Automotive Q-grade needed?
Medium Speed of Sound at 25°C
[m/s]
1.
Where Expected TOF = [2*(Fluid Level)] / (Fluid speed of sound)
Accuracy = (2 * accuracy * 10^-3) / (Fluid speed of sound)
2.
3. View the TI Design for this application: TIDA-00322
4. We recommend using the following sensors with your system:
Manufacturer | Sensor P/N | Resonant Frequency (kHz) | TDC1000 Register File |
---|---|---|---|
Steminc | SMD10T2R111WL | 1000 | Download |
Steminc | SMD15T21R111WL | 1000 | Download |
AudioWell | AW5Y15.5200AL145 | 1000 | Download |
AudioWell | AW5Y14200A | 1000 | Download |
CTD | TPC-D1020S | 1000 | Download |
5. Recommended documentations:
Automotive Q-grade needed?
Medium Speed of Sound at 25°C:
m/s
% Change in Medium:
1.
Where Expected TOF = (2 * distance) / [Speed of Sound * (1 ± (% change / 100))]
2.
3. View the TI Design for this application: TIDA-00322
4. We recommend using the following sensors with your system:
Manufacturer | Sensor P/N | Resonant Frequency (kHz) | TDC1000 Register File |
---|---|---|---|
Steminc | SMD10T2R111WL | 1000 | Download |
Steminc | SMD15T21R111WL | 1000 | Download |
AudioWell | AW5Y15.5200AL145 | 1000 | Download |
AudioWell | AW5Y14200A | 1000 | Download |
CTD | TPC-D1020S | 1000 | Download |
5. Recommended documentations:
xDc Placement:
xDc Spacing (L): m
Diameter (D): m
Medium Speed of Sound: m/s
Min. Flow Rate: l/h
Max. Flow Rate: l/h
Flow Rate Inaccuracy(%): %
1.
Where alpha = 45 degree
Flow rate [m/s] = (Flow rate [liter/hour]) * (1hour/3600 sec) * (0.001m³/1 liter) * [1/(π(D/2)²)]
tAB = (L) / [Speed of Sound + Flow Rate * cos(alpha)]
tBA = (L) / [Speed of Sound - Flow Rate * cos(alpha)]
ΔTOF = tAB - tBA
Max Flow Rate Accuracy = (accuracy / 100 ) * ΔTOF
2.
3. View the TI Design for this application: TIDM-ULTRASONIC-FLOW-TDC (Coming Soon!)
4. We recommend using the following sensors with your system:
Manufacturer | Sensor P/N | Resonant Frequency (kHz) | TDC1000 Register File |
---|---|---|---|
AudioWell | T/R975-US0014L353-01 | 1000 | Download |
AudioWell DN25 Brass Pipe for Heat Meters | AW5Y0980K04L193Z | 1000 | Download |
AudioWell DN20 Brass Pipe for Heat Meters | AW5Y0980K08L151Z | 1000 | Download |
Shenzen Yujie Elect. Co | HJ-2112.1M | 1000 | Download |
Morgan Ceramics | 09262/000 | 1000 | Download |
Morgan Ceramics | 09210/002 | 1000 | Download |
Morgan Ceramics | 09265-000 | 2000 | Download |
Morgan Ceramics | 09204-00 | 200 | Download |
Morgan Ceramics | 09262/000 | 100 | Download |
5. Recommended documentations: